5/9/2021 0 Comments Mazak Variaxis 730 Manual
Action Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses. 42 SPINDLE PARAMETER MALFUNCTION Cause The parameters that have been transferred from the NC unit to the spindle amplifier during NC power-on are not correct.SYSTEM ALARM 31 SERVO MALFUNCTION 1 32 SERVO PARAMETER MALFUNCTION 33 SERVO MALFUNCTION 2 34 SERVO MALFUNCTION 3 35 OVERLOAD 41 SPINDLE MALFUNCTION 1 42 SPINDLE PARAMETER MALFUNCTION 43 SPINDLE MALFUNCTION 2 44 SPINDLE MALFUNCTION 3 51 E2ROM MALFUNCTION 52 BATTERY ALARM 53 NC TEMPERATURE WARNING 54 DIO5V MALFUNCTION 56 SYSTEM SOFTWARE CHECKING 57 NO PLC 58 CORRUPT PLC 59 PLC STOPPED 66 PARAMETER MALFUNCTION 67 ILLEGAL HI-SPEED SYNCTAP AXIS 68 ILLEGAL HI-SPEED SYNCTAP SPDL 71 ILLEGAL SERVO PARAMETER 72 SERVO WARNING 81 ILLEGAL SPINDLE PARAMETER 82 SPINDLE WARNING System Drive Error 1 EMERGENCY STOP Cause Action 2 EMERGENCY STOP Cause Trouble has occurred in the hardware.If this does not clear the alarm status, require Mazak Technical Center or Technology Center to replace the defective hardware or cables.
EMERGENCY STOP Cause The emergency stop button on the operating panel has been pressed. Action Release the pressed state of the emergency stop button and reset the NC unit to its initial state. Mazak Variaxis 730 Software Andor CustomSYSTEM SOFTWARE ERROR Cause The contents of the system software andor custom software have been destroyed. Action Contact Mazak Technical Center or Technology Center. REMOTE IO ERROR Cause Action Contact Mazak Technical Center or Technology Center. SRAM MALFUNCTION Cause The S-RAM mounted on the CPU card has become abnormal. RAM MALFUNCTION Cause The RAM mounted on the CPU card has become abnormal. ABSOLUTE POSITION MALFUNCTION Cause The absolute position detection system has lost absolute position data. Action Require Mazak Technical Center or Technology Center to re-set the absolute position data. DETECTOR MALFUNCTION Cause The absolute position detection system has detected its detector error(s). Action Require Mazak Technical Center or Technology Center to replace the encoder or bettery. POSITION REFERENCE MALFUNCTION Cause The absolute position detection system has detected an error(s) by cross-checking the absolute position of its detector and the internal coordinate data of the NC unit. Require Mazak Technical Center or Technology Center to replace the battery. PRE-PROCESSOR MALFUNCTION Cause The software is not correctly working. Action Require Mazak Technical Center or Technology Center to re-write the NC system data. SYSTEM ERROR Cause Trouble has occurred during communication with the amplifiers or during communication data processing. Action Contact Mazak Technical Center or Technology Center with the information of the numbers (Alarm No. Sub No.) displayed in parentheses. AMPLIFIER NOT EQUIPPED Cause Amplifier power is not yet turned on. There is a discrepancy between the channel and rotary switch Nos. Action Check for an incorrectly connected cable, an incorrectly attached connector, an inadequate input supply voltage to the amplifier, an incorrect axis-number switch setting, etc. Check the settings of parameters N17, N18, SA43, and SA44 for incorrectness. SPINDLE SAFE OPER. SYSTEM ALARM Cause Trouble has occurred for the spindle in the mode of safety-speed operation. See the description of No. Action Contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses. SERVO MALFUNCTION 1 Cause The servo (power-off level) is abnormal. Action Require Mazak Technical Center or Technology Center to replace the servo amplifier. SERVO PARAMETER MALFUNCTION Cause The parameters that have been transferred from the NC unit to the servo amplifier during NC power-on are not correct. Action Require Mazak Technical Center or Technology Center to re-set the servo parameters. SERVO MALFUNCTION 2 Cause The servo (NC reset level) is abnormal. SERVO MALFUNCTION 3 Cause The servo (amplifier power-off level) is abnormal. OVERLOAD Cause An extraordinary overload has been detected. Action Check if any collision has occurred on the machine and perform the corresponding recovery, or check and reduce the cutting conditions. If other measures other than the above should be taken, contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses. SPINDLE MALFUNCTION 1 Cause The spindle (power-off level) is abnormal. SPINDLE PARAMETER MALFUNCTION Cause The parameters that have been transferred from the NC unit to the spindle amplifier during NC power-on are not correct.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |